| Parameter | Rating |
|---|---|
| Parameter | Value |
| Orderable part number | S506-32-R (BK- prefix = 100 pcs carton, BK1- = 1,000 pcs polybag) |
| Melting I2t (typical) | 0.0051 A2s |
| Agency | cURus (E19180, JDYX2); SEMKO; VDE; BSI; IMQ; KC; CCC |
| Time-delay class | T (time-lag) |
| Body | 5 x 20 mm glass tube, nickel-plated brass end caps |
| Design standard | IEC 60127-1 and 60127-2 |
| Typical DC cold resistance | 21 Ohm |
| Watts at rated current | 0.03 W |
| Voltage rating | 250 Vac |
| Current rating | 32 mA |
| Typical voltage drop | 1050 mV at rated current |
| Interrupting rating | 35 A at 250 Vac, 50 Hz |
Common installation contexts include:
What are the ratings of the S506-32-R?
0.03 A continuous at 250 Vac, interrupting rating 35 A at 250 Vac, 50 Hz.
Is the S506-32-R fast-acting or time-delay?
It is time-delay. It tolerates short inrush surges.
Can the S506-32-R be used on a higher fault-current circuit?
No — its interrupting rating is 35 A at 250 Vac, 50 Hz. Choose a part whose breaking capacity exceeds the prospective fault current.
Shenzhen Gaorunxin Technology Co., Ltd