Eaton S506-V-15-R 15 A 250 Vac Time-Delay Axial Lead Glass Tube Fuse
Eaton S506-V-15-R 15 A 250 Vac Time-Delay Axial Lead Glass Tube Fuse

Eaton S506-V-15-R 15 A 250 Vac Time-Delay Axial Lead Glass Tube Fuse

Share
pEaton S506-V-15-R — 15 A, 250 V, time-delay glass cartridge fuse, 150 A at 250 Vac, 50 Hz interrupting./p
    • Product Details
    • Download

    Eaton S506-V-15-R 15 A 250 Vac Time-Delay Axial Lead Glass Tube Fuse

    Eaton S506-V-15-R 15 A 250 Vac Time-Delay Axial Lead Glass Tube Fuse belongs to the Eaton range. It carries 15 A, rated 250 Vac, uses a time-delay element, in a glass body.

    Technical Data

    ParameterRating
    ParameterValue
    Orderable part numberS506-V-15-R (TR2- = 1,500 pcs on reel; BK- = 100 pcs carton)
    Lead spacing (dim B)38.1 mm +/- 0.38 (BK-) / 15.8 mm +/- 2.0 (TR2-)
    Voltage drop (typical)65.5 mV at rated current
    Current rating15 A A
    AgencycURus (E19180, JDYX2); PSE (JET)
    Overall length (cap to cap)21.1 mm +/- 0.81 mm
    Body diameter5.54 mm +/- 0.20 mm
    Interrupting rating150 A at 250 Vac, 50 Hz
    Lead diameter (dim A)0.81 mm tinned copper
    Rated voltage250 Vac
    DC cold resistance, typical0.004 Ohm
    Body5 x 20 mm glass tube, nickel-plated brass end caps
    Design standardIEC 60127-1 and 60127-2, T time-lag
    Typical melting I2t1091.7 A2s

    Design Notes

    • Interrupting capability is 150 A at 250 Vac, 50 Hz — confirm the circuit's prospective fault current stays below this.
    • Time-delay element rides through motor starting and capacitive inrush without nuisance opening.
    • Startup surges of several times rated current are tolerated for a short window.
    • Glass body lets you inspect the element after a fault.
    • Best kept for lower fault-current circuits where visual diagnosis matters.
    • Working voltage must stay at or below 250 Vac; a lower-rated part is not a safe substitute.
    • Do not upsize beyond 15 A to stop nuisance trips — fix the cause instead.

    Common Questions

    What are the ratings of the S506-V-15-R?

    15 A continuous at 250 Vac, interrupting rating 150 A at 250 Vac, 50 Hz.

    Is the S506-V-15-R fast-acting or time-delay?

    It is time-delay. It tolerates short inrush surges.

    Can the S506-V-15-R be used on a higher fault-current circuit?

    No — its interrupting rating is 150 A at 250 Vac, 50 Hz. Choose a part whose breaking capacity exceeds the prospective fault current.

    Shenzhen Gaorunxin Technology Co., Ltd