| Parameter | Rating |
|---|---|
| Parameter | Value |
| Orderable part number | S506-V-200-R (TR2- = 1,500 pcs on reel; BK- = 100 pcs carton) |
| Typical cold resistance | 1 Ohm |
| Body | 5 x 20 mm glass tube, nickel-plated brass end caps |
| Voltage rating | 250 Vac |
| Design standard | IEC 60127-1 and 60127-2, T time-lag |
| Lead diameter (dim A) | 0.65 mm tinned copper |
| Current rating | 200 mA A |
| I2t, typical melting | 0.114 A2s |
| Lead spacing (dim B) | 38.1 mm +/- 0.38 (BK-) / 15.8 mm +/- 2.0 (TR2-) |
| Overall length (cap to cap) | 21.1 mm +/- 0.81 mm |
| Body diameter | 5.54 mm +/- 0.20 mm |
| On-state drop, typical | 340 mV at rated current |
| Agency | cURus (E19180, JDYX2); SEMKO; VDE; BSI; IMQ; KC; CCC |
| Interrupting rating | 35 A at 250 Vac, 50 Hz |
What are the ratings of the S506-V-200-R?
200 mA continuous at 250 Vac, interrupting rating 35 A at 250 Vac, 50 Hz.
Is the S506-V-200-R fast-acting or time-delay?
It is time-delay. It tolerates short inrush surges.
Can the S506-V-200-R be used on a higher fault-current circuit?
No — its interrupting rating is 35 A at 250 Vac, 50 Hz. Choose a part whose breaking capacity exceeds the prospective fault current.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd