Eaton S506-V-80-R 80 mA 250 Vac Time-Delay Axial Lead Glass Tube Fuse
Eaton S506-V-80-R 80 mA 250 Vac Time-Delay Axial Lead Glass Tube Fuse

Eaton S506-V-80-R 80 mA 250 Vac Time-Delay Axial Lead Glass Tube Fuse

Share
pEaton S506-V-80-R — 80 mA, 250 V, time-delay glass cartridge fuse, 35 A at 250 Vac, 50 Hz interrupting./p
    • Product Details
    • Download

    Eaton S506-V-80-R 80 mA 250 Vac Time-Delay Axial Lead Glass Tube Fuse

    Eaton S506-V-80-R 80 mA 250 Vac Time-Delay Axial Lead Glass Tube Fuse belongs to the Eaton range. It carries 80 mA, rated 250 Vac, uses a time-delay element, in a glass body.

    Technical Data

    ParameterRating
    ParameterValue
    Orderable part numberS506-V-80-R (TR2- = 1,500 pcs on reel; BK- = 100 pcs carton)
    Interrupting rating35 A at 250 Vac, 50 Hz
    Rated voltage250 Vac
    Lead diameter (dim A)0.65 mm tinned copper
    DC cold resistance, typical4.42 Ohm
    Rated current80 mA A
    Typical voltage drop580 mV at rated current
    Typical melting I2t0.038 A2s
    AgencycURus (E19180, JDYX2); SEMKO; VDE; BSI; IMQ; KC; CCC
    Construction5 x 20 mm glass tube, nickel-plated brass end caps
    Lead spacing (dim B)38.1 mm +/- 0.38 (BK-) / 15.8 mm +/- 2.0 (TR2-)
    Body diameter5.54 mm +/- 0.20 mm
    Design standardIEC 60127-1 and 60127-2, T time-lag
    Overall length (cap to cap)21.1 mm +/- 0.81 mm

    Design Notes

    • Interrupting capability is 35 A at 250 Vac, 50 Hz — confirm the circuit's prospective fault current stays below this.
    • Time-delay element rides through motor starting and capacitive inrush without nuisance opening.
    • Startup surges of several times rated current are tolerated for a short window.
    • Glass body lets you inspect the element after a fault.
    • Best kept for lower fault-current circuits where visual diagnosis matters.
    • Working voltage must stay at or below 250 Vac; a lower-rated part is not a safe substitute.
    • Do not upsize beyond 80 mA to stop nuisance trips — fix the cause instead.

    Common Questions

    What are the ratings of the S506-V-80-R?

    80 mA continuous at 250 Vac, interrupting rating 35 A at 250 Vac, 50 Hz.

    Is the S506-V-80-R fast-acting or time-delay?

    It is time-delay. It tolerates short inrush surges.

    Can the S506-V-80-R be used on a higher fault-current circuit?

    No — its interrupting rating is 35 A at 250 Vac, 50 Hz. Choose a part whose breaking capacity exceeds the prospective fault current.

    Shenzhen Gaorunxin Technology Co., Ltd