Eaton S520-V-15-R 15 A 420 Vac Fast-Acting Axial Lead Ceramic Tube Fuse
Eaton S520-V-15-R 15 A 420 Vac Fast-Acting Axial Lead Ceramic Tube Fuse

Eaton S520-V-15-R 15 A 420 Vac Fast-Acting Axial Lead Ceramic Tube Fuse

Share
pEaton S520-V-15-R — 15 A, 420 V, fast-acting ceramic cartridge fuse, 300 A interrupting./p
    • Product Details
    • Download

    Eaton S520-V-15-R 15 A 420 Vac Fast-Acting Axial Lead Ceramic Tube Fuse

    Eaton S520-V-15-R 15 A 420 Vac Fast-Acting Axial Lead Ceramic Tube Fuse belongs to the Eaton range. It carries 15 A, rated 420 Vac, uses a fast-acting element, in a ceramic body.

    Technical Data

    ParameterRating
    ParameterValue
    Orderable part numberS520-V-15-R (TR2- = 1,500 pcs on reel)
    Voltage rating420 Vac
    Typical melting I2t220 A2s at 10 In
    AgencyUR E19180 (JDYX2); TUV T 50484820 02
    Interrupting rating at 420 Vac300 A
    Lead spacing (dim B)38.1 mm +/- 0.38 (BK-) / 15.8 mm +/- 2.0 (TR2-)
    Current rating15 A A
    Construction5 x 20 mm ceramic tube, nickel/silver plated brass ends
    Lead diameter (dim A)1.0 mm tinned copper
    Typical voltage drop195 mV at rated current
    Cold resistance (typical)6.8 mOhm
    Interrupting rating at 250 Vac1500 A

    Design Notes

    • Interrupting capability is 300 A — confirm the circuit's prospective fault current stays below this.
    • Fast element suits resistive and semiconductor loads rather than motors with high inrush.
    • Because it opens within milliseconds, downstream semiconductors see less let-through energy.
    • Ceramic body holds higher breaking capacity than glass at the same footprint.
    • It is the usual choice where prospective fault current is high.
    • Working voltage must stay at or below 420 Vac; a lower-rated part is not a safe substitute.
    • Do not upsize beyond 15 A to stop nuisance trips — fix the cause instead.

    Where It Is Used

    Typical places this fuse turns up:

    • EV
    • transformer

    Common Questions

    What are the ratings of the S520-V-15-R?

    15 A continuous at 420 Vac, interrupting rating 300 A.

    Is the S520-V-15-R fast-acting or time-delay?

    It is fast-acting. Expect it to open quickly on overload.

    Can the S520-V-15-R be used on a higher fault-current circuit?

    No — its interrupting rating is 300 A. Choose a part whose breaking capacity exceeds the prospective fault current.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products