Eaton SD3814-820-R 81.1 uH Shielded Inductor, Isat 0.296 A
Eaton SD3814-820-R 81.1 uH Shielded Inductor, Isat 0.296 A

Eaton SD3814-820-R 81.1 uH Shielded Inductor, Isat 0.296 A

Share
SD3814-820-R: shielded drum core inductor, 81.1 uH , 0.27 A Irms, Isat 0.296 A, DCR 2174 mOhm.
    • Product Details
    • Download

    Eaton SD3814-820-R 81.1 uH Shielded Inductor, Isat 0.296 A

    SD3814-820-R at a glance: shielded drum core inductor, 81.1 uH , 0.27 A Irms, Isat 0.296 A, DCR 2174 mOhm.

    Specification Table

    ParameterValue
    Orderable part numberSD3814-820-R
    Rated inductance82 uH
    OCL (open circuit inductance)81.1 uH
    DCR typical @ +20 °C2174 mOhm
    Irms (DC, 40 °C rise)0.27 A
    Isat0.296 A
    Volt-time rating32 V-us
    Package38 x 14 mm
    MountingSurface mount
    Operating temperature-40 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4318

    Outline Drawing

    SD3814-820-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4318: outline with
    rated mm dimensions, pad layout and marking.

    What the Numbers Mean

    A shielded drum core inductor: the winding sits on a drum-shaped ferrite core and a shield sleeve closes the magnetic path around it. That is what keeps the radiated field low enough to place the part next to other circuitry.

    At 0.27 A the winding dissipates about 0.158 W in copper using the typical DCR of 2174 mOhm. That is the DC floor of the loss budget – ripple and core loss come on top.

    The core stores about 3.55 uJ at the saturation point, which is the energy available to bridge a load step.

    Within the SD3814 family this is value 15 of 21, in a range from 0.36 uH to 3814 uH.

    Series Positioning

    The SD family is the shielded drum core range: SMD parts from about 3 mm to 8 mm, covering sub-microhenry to hundreds of microhenry at currents from a few hundred milliamps to several amps.

    • The shield reduces but does not eliminate the external field. Check the layout against the EMC plan before placing sensitive traces close.
    • Typical applications: mobile phones; digital cameras; media players; small lcd displays; led driver and led flash circuits.
    • Design note: on a shielded drum the Isat and Irms limits can differ a lot. Size against whichever is lower for the application.

    Frequently Asked Questions

    Why is Isat lower than Irms on some rows?
    They are different limits: Irms is thermal, Isat is magnetic. On a high-inductance part the core saturates before the winding overheats.

    Why is Isat lower than Irms on some rows?
    They are different limits: Irms is thermal, Isat is magnetic. On a high-inductance part the core saturates before the winding overheats.

    What is the Volt-us column?
    The applied volt-time product that produces a defined core loss. It is the figure to compare against the converter waveform at the switching frequency.

    Shenzhen Gaorunxin Technology Co., Ltd