Eaton SD8328-220-R 21.1 uH Shielded Inductor, 1.85 A
Eaton SD8328-220-R 21.1 uH Shielded Inductor, 1.85 A

Eaton SD8328-220-R 21.1 uH Shielded Inductor, 1.85 A

Share
SD8328-220-R: shielded drum core inductor, 21.1 uH , 1.85 A Irms, Isat 1.7 A, DCR 76000 mOhm.
    • Product Details
    • Download

    Eaton SD8328-220-R 21.1 uH Shielded Inductor, 1.85 A

    SD8328-220-R at a glance: shielded drum core inductor, 21.1 uH , 1.85 A Irms, Isat 1.7 A, DCR 76000 mOhm.

    Key Specifications

    ParameterValue
    Orderable part numberSD8328-220-R
    Rated inductance22 uH
    OCL (open circuit inductance)21.1 uH
    DCR typical @ +20 °C76000 mOhm
    DCR maximum @ +20 °C99000 mOhm
    Irms (DC, 40 °C rise)1.85 A
    Isat1.7 A
    K-factor4.9
    Package9.5 x 8.3 x 3 mm
    MountingSurface mount
    Operating temperature-40 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4140

    Outline Drawing

    SD8328-220-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4140: outline with
    rated mm dimensions, pad layout and marking.

    How to Read These Ratings

    A shielded drum core inductor: the winding sits on a drum-shaped ferrite core and a shield sleeve closes the magnetic path around it. That is what keeps the radiated field low enough to place the part next to other circuitry.

    At 1.85 A the winding dissipates about 260 W in copper using the typical DCR of 76000 mOhm. That is the DC floor of the loss budget – ripple and core loss come on top.

    The core stores about 30.5 uJ at the saturation point, which is the energy available to bridge a load step.

    The K-factor of 4.9 converts inductance and ripple into flux swing; read the core-loss curve at that amplitude.

    Within the SD8328 family this is value 7 of 11, in a range from 2.7 uH to 97 uH.

    Positioning in the Range

    The SD family is the shielded drum core range: SMD parts from about 3 mm to 8 mm, covering sub-microhenry to hundreds of microhenry at currents from a few hundred milliamps to several amps.

    • The shield reduces but does not eliminate the external field. Check the layout against the EMC plan before placing sensitive traces close.
    • Typical applications: buck or boost inductor; noise filtering output filter chokes; notebook and laptop power/display; lcd monitors/displays/televisions; battery chargers, lcd bias supplies.
    • Design note: on a shielded drum the Isat and Irms limits can differ a lot. Size against whichever is lower for the application.

    Frequently Asked Questions

    What does the shield actually do?
    It closes the magnetic return path around the drum, which reduces the fringing field that would otherwise couple into nearby traces.

    What is the Volt-us column?
    The applied volt-time product that produces a defined core loss. It is the figure to compare against the converter waveform at the switching frequency.

    What is the Volt-us column?