| Parameter | Value |
|---|---|
| Orderable part number | SDCLA1V4018-150-R |
| Inductance | 15 uH ±20% |
| FLL minimum (at Isat) | 8.4 uH |
| DCR typical @ +20 °C | 210 mOhm |
| Irms (DC, 40 °C rise) | 0.85 A |
| Isat | 1.1 A |
| SRF typical | 18 MHz |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +125 °C |
| Qualification | AEC-Q200 |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data ELX1098 |

Drawing reproduced from Eaton Technical Data ELX1098: outline with
rated mm dimensions, pad layout and marking.
This part is used on body electronics and ADAS power rails where the inductor has to be qualified, shielded enough for EMC, and small enough to fit beside the regulator.
At 0.85 A the winding dissipates about 0.152 W in copper using the typical DCR of 210 mOhm. That is the DC floor of the loss budget – ripple and core loss come on top.
The core stores about 9.08 uJ at the saturation point, which is the energy available to bridge a load step.
Self-resonance is 18 MHz typical. Keep the operating band, and the harmonics that carry energy, below it.
Within the SDCLA1V4018 family this is value 8 of 9, in a range from 1 uH to 22 uH.
The SDCA family is the automotive semi-shielded range: the same construction as the commercial parts, qualified to AEC-Q200 and characterised across the temperature range.
What is the FLL column for?
Full-load inductance at saturation current. Use it for the ripple calculation at maximum load rather than the zero-bias value.
How do I check the hot corner?
Use Isat at the highest operating temperature and the maximum DCR at that temperature. The room-temperature row is the optimistic one.
How do I check the hot corner?
Use Isat at the highest operating temperature and the maximum DCR at that temperature. The room-temperature row is the optimistic one.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd