SM8S11A: transient voltage suppressor diode, 11 V standoff, 18.2 V clamp, 363 A pulse, 6600 W, unidirectional.
    • Product Details
    • Download

    Eaton SM8S11A Transient Voltage Suppressor 11 V

    SM8S11A at a glance: transient voltage suppressor diode, 11 V standoff, 18.2 V clamp, 363 A pulse, 6600 W, unidirectional.

    Key Specifications

    ParameterValue
    Orderable part numberSM8S11A
    Standoff voltage (VR)11 V
    Leakage current at VR5 uA
    Leakage current at VR, +175 °C150 uA
    Breakdown voltage at IT12.2 V to 13.5 V
    Test current (IT)5 mA
    Clamping voltage at IPP18.2 V
    Peak pulse current363 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us6600 W
    PackageSMTO-263 (D2PAK)
    MountingSurface mount
    Operating temperature-55 °C to +175 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1060

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1060; the package line above is the
    body the part is built in.

    How to Read These Ratings

    A TVS is chosen after the surge source is known. The pulse current in the table is the current the part can take, so the source impedance and the coupling network decide whether the clamp column is the number the protected circuit experiences.

    The breakdown window spans 10.66 percent, from 12.2 V to 13.5 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 11 V standing the leakage is at most 5 uA, so the part draws 0.055 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SM8S family this is item 3 of 38 in the Eaton catalogue.

    What This Family Is For

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • The standoff voltage is a DC limit. On an AC line the peak of the sine has to stay below it, which for a 120 V RMS line means a part rated well above 170 V.
    • Bidirectional parts are two junctions back to back in one package. They clamp symmetrically, at the cost of roughly double the capacitance of a unidirectional part of the same die.

    Frequently Asked Questions

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.