SM8S13AH: transient voltage suppressor diode, 13 V standoff, 21.5 V clamp, 307 A pulse, 6600 W, unidirectional.
    • Product Details
    • Download

    Eaton SM8S13AH 13 V 6600 W TVS Diode

    SM8S13AH at a glance: transient voltage suppressor diode, 13 V standoff, 21.5 V clamp, 307 A pulse, 6600 W, unidirectional.

    Electrical Specifications

    ParameterValue
    Orderable part numberSM8S13AH
    Standoff voltage (VR)13 V
    Leakage current at VR5 uA
    Leakage current at VR, +175 °C150 uA
    Breakdown voltage at IT14.4 V to 15.9 V
    Test current (IT)5 mA
    Clamping voltage at IPP21.5 V
    Peak pulse current307 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us6600 W
    PackageSMTO-263 (D2PAK)
    MountingSurface mount
    Operating temperature-55 °C to +175 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1060

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1060; the package line above is the
    body the part is built in.

    How to Read These Ratings

    These parts are avalanching junctions, so they clamp harder than a varistor and recover without the voltage drift a metal oxide part shows after a surge. The trade is capacitance and a sharper failure mode.

    The breakdown window spans 10.42 percent, from 14.4 V to 15.9 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 13 V standing the leakage is at most 5 uA, so the part draws 0.065 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SM8S family this is item 8 of 38 in the Eaton catalogue.

    What This Family Is For

    The part goes across the line after the fuse, with the return path as short as the layout allows. Every centimetre of trace between the connector and the diode adds inductance, and the clamp the circuit sees is the diode clamp plus L di/dt.

    • The pulse current is quoted for one waveform. A different waveform changes the allowable current, and the derating curve, not the single number, is the guide.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.