Eaton SM8S13C Transient Voltage Suppressor 13 V
Eaton SM8S13C Transient Voltage Suppressor 13 V

Eaton SM8S13C Transient Voltage Suppressor 13 V

Share
SM8S13C: transient voltage suppressor diode, 13 V standoff, 21.5 V clamp, 307 A pulse, 6600 W, bidirectional.
    • Product Details
    • Download

    Eaton SM8S13C Transient Voltage Suppressor 13 V

    SM8S13C at a glance: transient voltage suppressor diode, 13 V standoff, 21.5 V clamp, 307 A pulse, 6600 W, bidirectional.

    Electrical Specifications

    ParameterValue
    Orderable part numberSM8S13C
    Standoff voltage (VR)13 V
    Leakage current at VR5 uA
    Leakage current at VR, +175 °C150 uA
    Breakdown voltage at IT14.4 V to 15.9 V
    Test current (IT)5 mA
    Clamping voltage at IPP21.5 V
    Peak pulse current307 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us6600 W
    PackageSMTO-263 (D2PAK)
    MountingSurface mount
    Operating temperature-55 °C to +175 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1060

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1060; the package line above is the
    body the part is built in.

    The Figures Explained

    These parts are avalanching junctions, so they clamp harder than a varistor and recover without the voltage drift a metal oxide part shows after a surge. The trade is capacitance and a sharper failure mode.

    The breakdown window spans 10.42 percent, from 14.4 V to 15.9 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 13 V standing the leakage is at most 5 uA, so the part draws 0.065 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SM8S family this is item 3 of 30 in the Eaton catalogue.

    Series Positioning

    The part goes across the line after the fuse, with the return path as short as the layout allows. Every centimetre of trace between the connector and the diode adds inductance, and the clamp the circuit sees is the diode clamp plus L di/dt.

    • The standoff voltage is a DC limit. On an AC line the peak of the sine has to stay below it, which for a 120 V RMS line means a part rated well above 170 V.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products