SM8S14A: transient voltage suppressor diode, 14 V standoff, 23.2 V clamp, 284 A pulse, 6600 W, unidirectional.
    • Product Details
    • Download

    Eaton SM8S14A 14 V 6600 W TVS Diode

    SM8S14A at a glance: transient voltage suppressor diode, 14 V standoff, 23.2 V clamp, 284 A pulse, 6600 W, unidirectional.

    Electrical Specifications

    ParameterValue
    Orderable part numberSM8S14A
    Standoff voltage (VR)14 V
    Leakage current at VR5 uA
    Leakage current at VR, +175 °C150 uA
    Breakdown voltage at IT15.6 V to 17.2 V
    Test current (IT)5 mA
    Clamping voltage at IPP23.2 V
    Peak pulse current284 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us6600 W
    PackageSMTO-263 (D2PAK)
    MountingSurface mount
    Operating temperature-55 °C to +175 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1060

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1060; the package line above is the
    body the part is built in.

    Reading the Data Sheet

    The standoff voltage has to sit above the highest steady state level on the line, including regulation and ripple. The breakdown voltage is then one diode drop above that, and the clamp is what the downstream circuit actually sees.

    The breakdown window spans 10.26 percent, from 15.6 V to 17.2 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 14 V standing the leakage is at most 5 uA, so the part draws 0.07 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SM8S family this is item 9 of 38 in the Eaton catalogue.

    What This Family Is For

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.