SM8S17A: transient voltage suppressor diode, 17 V standoff, 27.6 V clamp, 239 A pulse, 6600 W, unidirectional.
    • Product Details
    • Download

    Eaton SM8S17A 17 V 6600 W TVS Diode

    SM8S17A at a glance: transient voltage suppressor diode, 17 V standoff, 27.6 V clamp, 239 A pulse, 6600 W, unidirectional.

    Key Specifications

    ParameterValue
    Orderable part numberSM8S17A
    Standoff voltage (VR)17 V
    Leakage current at VR5 uA
    Leakage current at VR, +175 °C150 uA
    Breakdown voltage at IT18.9 V to 20.9 V
    Test current (IT)5 mA
    Clamping voltage at IPP27.6 V
    Peak pulse current239 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us6600 W
    PackageSMTO-263 (D2PAK)
    MountingSurface mount
    Operating temperature-55 °C to +175 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1060

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1060; the package line above is the
    body the part is built in.

    The Figures Explained

    The standoff voltage has to sit above the highest steady state level on the line, including regulation and ripple. The breakdown voltage is then one diode drop above that, and the clamp is what the downstream circuit actually sees.

    The breakdown window spans 10.58 percent, from 18.9 V to 20.9 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 17 V standing the leakage is at most 5 uA, so the part draws 0.085 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SM8S family this is item 15 of 38 in the Eaton catalogue.

    Positioning in the Range

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.