Eaton SM8S18C Transient Voltage Suppressor 18 V
Eaton SM8S18C Transient Voltage Suppressor 18 V

Eaton SM8S18C Transient Voltage Suppressor 18 V

Share
SM8S18C: transient voltage suppressor diode, 18 V standoff, 29.2 V clamp, 226 A pulse, 6600 W, bidirectional.
    • Product Details
    • Download

    Eaton SM8S18C Transient Voltage Suppressor 18 V

    SM8S18C at a glance: transient voltage suppressor diode, 18 V standoff, 29.2 V clamp, 226 A pulse, 6600 W, bidirectional.

    Key Specifications

    ParameterValue
    Orderable part numberSM8S18C
    Standoff voltage (VR)18 V
    Leakage current at VR5 uA
    Leakage current at VR, +175 °C150 uA
    Breakdown voltage at IT20 V to 22.1 V
    Test current (IT)5 mA
    Clamping voltage at IPP29.2 V
    Peak pulse current226 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us6600 W
    PackageSMTO-263 (D2PAK)
    MountingSurface mount
    Operating temperature-55 °C to +175 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1060

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1060; the package line above is the
    body the part is built in.

    How to Read These Ratings

    A transient voltage suppressor is a diode biased so that it stays off at the working voltage and breaks down in a surge. The three numbers that decide whether it fits are the standoff voltage, the breakdown window and the clamping voltage at the pulse current you expect.

    The breakdown window spans 10.5 percent, from 20 V to 22.1 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 18 V standing the leakage is at most 5 uA, so the part draws 0.09 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SM8S family this is item 13 of 30 in the Eaton catalogue.

    Where This Series Fits

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • The standoff voltage is a DC limit. On an AC line the peak of the sine has to stay below it, which for a 120 V RMS line means a part rated well above 170 V.
    • The breakdown window is deliberately wide so that production spread does not leave parts conducting at the standoff voltage. Design to the minimum breakdown, not the typical.

    Frequently Asked Questions

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.