Eaton SM8S20C Transient Voltage Suppressor 20 V
Eaton SM8S20C Transient Voltage Suppressor 20 V

Eaton SM8S20C Transient Voltage Suppressor 20 V

Share
SM8S20C: transient voltage suppressor diode, 20 V standoff, 32.4 V clamp, 204 A pulse, 6600 W, bidirectional.
    • Product Details
    • Download

    Eaton SM8S20C Transient Voltage Suppressor 20 V

    SM8S20C at a glance: transient voltage suppressor diode, 20 V standoff, 32.4 V clamp, 204 A pulse, 6600 W, bidirectional.

    Specification Table

    ParameterValue
    Orderable part numberSM8S20C
    Standoff voltage (VR)20 V
    Leakage current at VR5 uA
    Leakage current at VR, +175 °C150 uA
    Breakdown voltage at IT22.2 V to 24.5 V
    Test current (IT)5 mA
    Clamping voltage at IPP32.4 V
    Peak pulse current204 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us6600 W
    PackageSMTO-263 (D2PAK)
    MountingSurface mount
    Operating temperature-55 °C to +175 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1060

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1060; the package line above is the
    body the part is built in.

    What the Numbers Mean

    The peak pulse power rating is a 10/1000 microsecond figure: a 400 W part takes 400 W for one millisecond, not continuously. Shorter pulses allow more current, longer ones less, which is what the derating curves in the data sheet show.

    The breakdown window spans 10.36 percent, from 22.2 V to 24.5 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 20 V standing the leakage is at most 5 uA, so the part draws 0.1 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SM8S family this is item 15 of 30 in the Eaton catalogue.

    What This Family Is For

    The part goes across the line after the fuse, with the return path as short as the layout allows. Every centimetre of trace between the connector and the diode adds inductance, and the clamp the circuit sees is the diode clamp plus L di/dt.

    • The standoff voltage is a DC limit. On an AC line the peak of the sine has to stay below it, which for a 120 V RMS line means a part rated well above 170 V.
    • The breakdown window is deliberately wide so that production spread does not leave parts conducting at the standoff voltage. Design to the minimum breakdown, not the typical.

    Frequently Asked Questions

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.