Eaton SM8S26CAH TVS Diode, 42.1 V Clamp
Eaton SM8S26CAH TVS Diode, 42.1 V Clamp

Eaton SM8S26CAH TVS Diode, 42.1 V Clamp

Share
SM8S26CAH: transient voltage suppressor diode, 26 V standoff, 42.1 V clamp, 157 A pulse, 6600 W, bidirectional.
    • Product Details
    • Download

    Eaton SM8S26CAH TVS Diode, 42.1 V Clamp

    SM8S26CAH at a glance: transient voltage suppressor diode, 26 V standoff, 42.1 V clamp, 157 A pulse, 6600 W, bidirectional.

    Key Specifications

    ParameterValue
    Orderable part numberSM8S26CAH
    Standoff voltage (VR)26 V
    Leakage current at VR5 uA
    Leakage current at VR, +175 °C150 uA
    Breakdown voltage at IT28.9 V to 31.9 V
    Test current (IT)5 mA
    Clamping voltage at IPP42.1 V
    Peak pulse current157 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us6600 W
    PackageSMTO-263 (D2PAK)
    MountingSurface mount
    Operating temperature-55 °C to +175 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1060

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1060; the package line above is the
    body the part is built in.

    The Figures Explained

    The peak pulse power rating is a 10/1000 microsecond figure: a 400 W part takes 400 W for one millisecond, not continuously. Shorter pulses allow more current, longer ones less, which is what the derating curves in the data sheet show.

    The breakdown window spans 10.38 percent, from 28.9 V to 31.9 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 26 V standing the leakage is at most 5 uA, so the part draws 0.13 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SM8S family this is item 22 of 30 in the Eaton catalogue.

    Where This Series Fits

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • The standoff voltage is a DC limit. On an AC line the peak of the sine has to stay below it, which for a 120 V RMS line means a part rated well above 170 V.
    • The breakdown window is deliberately wide so that production spread does not leave parts conducting at the standoff voltage. Design to the minimum breakdown, not the typical.

    Frequently Asked Questions

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.