Eaton SM8S36C Transient Voltage Suppressor 36 V
Eaton SM8S36C Transient Voltage Suppressor 36 V

Eaton SM8S36C Transient Voltage Suppressor 36 V

Share
SM8S36C: transient voltage suppressor diode, 36 V standoff, 58.1 V clamp, 114 A pulse, 6600 W, bidirectional.
    • Product Details
    • Download

    Eaton SM8S36C Transient Voltage Suppressor 36 V

    SM8S36C at a glance: transient voltage suppressor diode, 36 V standoff, 58.1 V clamp, 114 A pulse, 6600 W, bidirectional.

    Electrical Specifications

    ParameterValue
    Orderable part numberSM8S36C
    Standoff voltage (VR)36 V
    Leakage current at VR5 uA
    Leakage current at VR, +175 °C150 uA
    Breakdown voltage at IT40 V to 44.2 V
    Test current (IT)5 mA
    Clamping voltage at IPP58.1 V
    Peak pulse current114 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us6600 W
    PackageSMTO-263 (D2PAK)
    MountingSurface mount
    Operating temperature-55 °C to +175 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1060

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1060; the package line above is the
    body the part is built in.

    How to Read These Ratings

    A TVS is chosen after the surge source is known. The pulse current in the table is the current the part can take, so the source impedance and the coupling network decide whether the clamp column is the number the protected circuit experiences.

    The breakdown window spans 10.5 percent, from 40 V to 44.2 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 36 V standing the leakage is at most 5 uA, so the part draws 0.18 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SM8S family this is item 29 of 30 in the Eaton catalogue.

    Series Positioning

    The part goes across the line after the fuse, with the return path as short as the layout allows. Every centimetre of trace between the connector and the diode adds inductance, and the clamp the circuit sees is the diode clamp plus L di/dt.

    • The standoff voltage is a DC limit. On an AC line the peak of the sine has to stay below it, which for a 120 V RMS line means a part rated well above 170 V.
    • The breakdown window is deliberately wide so that production spread does not leave parts conducting at the standoff voltage. Design to the minimum breakdown, not the typical.

    Frequently Asked Questions

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.