Eaton SM8S43AH 43 V 6600 W TVS Diode
Eaton SM8S43AH 43 V 6600 W TVS Diode

Eaton SM8S43AH 43 V 6600 W TVS Diode

Share
SM8S43AH: transient voltage suppressor diode, 43 V standoff, 69.4 V clamp, 95.1 A pulse, 6600 W, unidirectional.
    • Product Details
    • Download

    Eaton SM8S43AH 43 V 6600 W TVS Diode

    SM8S43AH at a glance: transient voltage suppressor diode, 43 V standoff, 69.4 V clamp, 95.1 A pulse, 6600 W, unidirectional.

    Key Specifications

    ParameterValue
    Orderable part numberSM8S43AH
    Standoff voltage (VR)43 V
    Leakage current at VR5 uA
    Leakage current at VR, +175 °C150 uA
    Breakdown voltage at IT47.8 V to 52.8 V
    Test current (IT)5 mA
    Clamping voltage at IPP69.4 V
    Peak pulse current95.1 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us6600 W
    PackageSMTO-263 (D2PAK)
    MountingSurface mount
    Operating temperature-55 °C to +175 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1060

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1060; the package line above is the
    body the part is built in.

    How to Read These Ratings

    A transient voltage suppressor is a diode biased so that it stays off at the working voltage and breaks down in a surge. The three numbers that decide whether it fits are the standoff voltage, the breakdown window and the clamping voltage at the pulse current you expect.

    The breakdown window spans 10.46 percent, from 47.8 V to 52.8 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 43 V standing the leakage is at most 5 uA, so the part draws 0.215 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SM8S family this is item 38 of 38 in the Eaton catalogue.

    Positioning in the Range

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products