    SM8T20AH at a glance: transient voltage suppressor diode, 20 V standoff, 32.4 V clamp, 247 A pulse, 8000 W, unidirectional.

    Electrical Specifications

    ParameterValue
    Orderable part numberSM8T20AH
    Standoff voltage (VR)20 V
    Leakage current at VR5 uA
    Leakage current at VR, +175 °C150 uA
    Breakdown voltage at IT22.2 V to 24.5 V
    Test current (IT)5 mA
    Clamping voltage at IPP32.4 V
    Peak pulse current247 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us8000 W
    PackageSMTO-263 (D2PAK)
    MountingSurface mount
    Operating temperature-55 °C to +175 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1061

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1061; the package line above is the
    body the part is built in.

    Reading the Data Sheet

    The peak pulse power rating is a 10/1000 microsecond figure: a 400 W part takes 400 W for one millisecond, not continuously. Shorter pulses allow more current, longer ones less, which is what the derating curves in the data sheet show.

    The breakdown window spans 10.36 percent, from 22.2 V to 24.5 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 20 V standing the leakage is at most 5 uA, so the part draws 0.1 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SM8T family this is item 2 of 22 in the Eaton catalogue.

    Positioning in the Range

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • The pulse current is quoted for one waveform. A different waveform changes the allowable current, and the derating curve, not the single number, is the guide.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.