Eaton SM8T33AH 33 V 8000 W TVS Diode
Eaton SM8T33AH 33 V 8000 W TVS Diode

Eaton SM8T33AH 33 V 8000 W TVS Diode

Share
SM8T33AH: transient voltage suppressor diode, 33 V standoff, 53.3 V clamp, 150 A pulse, 8000 W, unidirectional.
    • Product Details
    • Download

    Eaton SM8T33AH 33 V 8000 W TVS Diode

    SM8T33AH at a glance: transient voltage suppressor diode, 33 V standoff, 53.3 V clamp, 150 A pulse, 8000 W, unidirectional.

    Specification Table

    ParameterValue
    Orderable part numberSM8T33AH
    Standoff voltage (VR)33 V
    Leakage current at VR5 uA
    Leakage current at VR, +175 °C150 uA
    Breakdown voltage at IT36.7 V to 40.6 V
    Test current (IT)5 mA
    Clamping voltage at IPP53.3 V
    Peak pulse current150 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us8000 W
    PackageSMTO-263 (D2PAK)
    MountingSurface mount
    Operating temperature-55 °C to +175 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1061

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1061; the package line above is the
    body the part is built in.

    How to Read These Ratings

    These parts are avalanching junctions, so they clamp harder than a varistor and recover without the voltage drift a metal oxide part shows after a surge. The trade is capacitance and a sharper failure mode.

    The breakdown window spans 10.63 percent, from 36.7 V to 40.6 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 33 V standing the leakage is at most 5 uA, so the part draws 0.165 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SM8T family this is item 16 of 22 in the Eaton catalogue.

    Series Positioning

    The part goes across the line after the fuse, with the return path as short as the layout allows. Every centimetre of trace between the connector and the diode adds inductance, and the clamp the circuit sees is the diode clamp plus L di/dt.

    • The standoff voltage is a DC limit. On an AC line the peak of the sine has to stay below it, which for a 120 V RMS line means a part rated well above 170 V.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.