Eaton SMAJ18CAH Transient Voltage Suppressor 18 V
Eaton SMAJ18CAH Transient Voltage Suppressor 18 V

Eaton SMAJ18CAH Transient Voltage Suppressor 18 V

Share
SMAJ18CAH: transient voltage suppressor diode, 18 V standoff, 29.2 V clamp, 13.7 A pulse, 400 W, bidirectional.
    • Product Details
    • Download

    Eaton SMAJ18CAH Transient Voltage Suppressor 18 V

    SMAJ18CAH at a glance: transient voltage suppressor diode, 18 V standoff, 29.2 V clamp, 13.7 A pulse, 400 W, bidirectional.

    Specification Table

    ParameterValue
    Orderable part numberSMAJ18CAH
    Standoff voltage (VR)18 V
    Leakage current at VR1 uA
    Breakdown voltage at IT20 V to 22.1 V
    Test current (IT)1 mA
    Clamping voltage at IPP29.2 V
    Peak pulse current13.7 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us400 W
    PackageSMA (DO-214AC)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1062

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1062; the package line above is the
    body the part is built in.

    The Figures Explained

    These parts are avalanching junctions, so they clamp harder than a varistor and recover without the voltage drift a metal oxide part shows after a surge. The trade is capacitance and a sharper failure mode.

    The breakdown window spans 10.5 percent, from 20 V to 22.1 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 18 V standing the leakage is at most 1 uA, so the part draws 0.018 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMAJ family this is item 42 of 151 in the Eaton catalogue.

    Where This Series Fits

    The part goes across the line after the fuse, with the return path as short as the layout allows. Every centimetre of trace between the connector and the diode adds inductance, and the clamp the circuit sees is the diode clamp plus L di/dt.

    • The pulse current is quoted for one waveform. A different waveform changes the allowable current, and the derating curve, not the single number, is the guide.
    • The breakdown window is deliberately wide so that production spread does not leave parts conducting at the standoff voltage. Design to the minimum breakdown, not the typical.

    Frequently Asked Questions

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products