Eaton SMAJ190CA 190 V 400 W TVS Diode
Eaton SMAJ190CA 190 V 400 W TVS Diode

Eaton SMAJ190CA 190 V 400 W TVS Diode

Share
SMAJ190CA: transient voltage suppressor diode, 190 V standoff, 308 V clamp, 1.3 A pulse, 400 W, bidirectional.
    • Product Details
    • Download

    Eaton SMAJ190CA 190 V 400 W TVS Diode

    SMAJ190CA at a glance: transient voltage suppressor diode, 190 V standoff, 308 V clamp, 1.3 A pulse, 400 W, bidirectional.

    Key Specifications

    ParameterValue
    Orderable part numberSMAJ190CA
    Standoff voltage (VR)190 V
    Leakage current at VR1 uA
    Breakdown voltage at IT211 V to 233 V
    Test current (IT)1 mA
    Clamping voltage at IPP308 V
    Peak pulse current1.3 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us400 W
    PackageSMA (DO-214AC)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1564

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1564; the package line above is the
    body the part is built in.

    The Figures Explained

    The standoff voltage has to sit above the highest steady state level on the line, including regulation and ripple. The breakdown voltage is then one diode drop above that, and the clamp is what the downstream circuit actually sees.

    The breakdown window spans 10.43 percent, from 211 V to 233 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 190 V standing the leakage is at most 1 uA, so the part draws 0.19 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMAJ family this is item 129 of 151 in the Eaton catalogue.

    Series Positioning

    The part goes across the line after the fuse, with the return path as short as the layout allows. Every centimetre of trace between the connector and the diode adds inductance, and the clamp the circuit sees is the diode clamp plus L di/dt.

    • The standoff voltage is a DC limit. On an AC line the peak of the sine has to stay below it, which for a 120 V RMS line means a part rated well above 170 V.
    • The breakdown window is deliberately wide so that production spread does not leave parts conducting at the standoff voltage. Design to the minimum breakdown, not the typical.

    Frequently Asked Questions

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products