Eaton SMAJ20A 20 V 400 W TVS Diode
Eaton SMAJ20A 20 V 400 W TVS Diode

Eaton SMAJ20A 20 V 400 W TVS Diode

Share
SMAJ20A: transient voltage suppressor diode, 20 V standoff, 32.4 V clamp, 12.3 A pulse, 400 W, unidirectional.
    • Product Details
    • Download

    Eaton SMAJ20A 20 V 400 W TVS Diode

    SMAJ20A at a glance: transient voltage suppressor diode, 20 V standoff, 32.4 V clamp, 12.3 A pulse, 400 W, unidirectional.

    Key Specifications

    ParameterValue
    Orderable part numberSMAJ20A
    Standoff voltage (VR)20 V
    Leakage current at VR1 uA
    Breakdown voltage at IT22.2 V to 24.5 V
    Test current (IT)1 mA
    Clamping voltage at IPP32.4 V
    Peak pulse current12.3 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us400 W
    PackageSMA (DO-214AC)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1564

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1564; the package line above is the
    body the part is built in.

    The Figures Explained

    These parts are avalanching junctions, so they clamp harder than a varistor and recover without the voltage drift a metal oxide part shows after a surge. The trade is capacitance and a sharper failure mode.

    The breakdown window spans 10.36 percent, from 22.2 V to 24.5 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 20 V standing the leakage is at most 1 uA, so the part draws 0.02 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMAJ family this is item 44 of 151 in the Eaton catalogue.

    Series Positioning

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.