Eaton SMAJ33A 33 V 400 W TVS Diode
Eaton SMAJ33A 33 V 400 W TVS Diode

Eaton SMAJ33A 33 V 400 W TVS Diode

Share
SMAJ33A: transient voltage suppressor diode, 33 V standoff, 53.3 V clamp, 7.5 A pulse, 400 W, unidirectional.
    • Product Details
    • Download

    Eaton SMAJ33A 33 V 400 W TVS Diode

    SMAJ33A at a glance: transient voltage suppressor diode, 33 V standoff, 53.3 V clamp, 7.5 A pulse, 400 W, unidirectional.

    Ratings at a Glance

    ParameterValue
    Orderable part numberSMAJ33A
    Standoff voltage (VR)33 V
    Leakage current at VR1 uA
    Breakdown voltage at IT36.7 V to 40.6 V
    Test current (IT)1 mA
    Clamping voltage at IPP53.3 V
    Peak pulse current7.5 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us400 W
    PackageSMA (DO-214AC)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1564

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1564; the package line above is the
    body the part is built in.

    Reading the Data Sheet

    The standoff voltage has to sit above the highest steady state level on the line, including regulation and ripple. The breakdown voltage is then one diode drop above that, and the clamp is what the downstream circuit actually sees.

    The breakdown window spans 10.63 percent, from 36.7 V to 40.6 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 33 V standing the leakage is at most 1 uA, so the part draws 0.033 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMAJ family this is item 62 of 151 in the Eaton catalogue.

    Series Positioning

    Keep the ground connection on the same layer as the diode. A clamp that has to travel through a via to reach the return plane loses most of its advantage at the edge speeds an ESD event produces.

    • The standoff voltage is a DC limit. On an AC line the peak of the sine has to stay below it, which for a 120 V RMS line means a part rated well above 170 V.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products