Eaton SMAJ400CAH TVS Diode, 648 V Clamp
Eaton SMAJ400CAH TVS Diode, 648 V Clamp

Eaton SMAJ400CAH TVS Diode, 648 V Clamp

Share
SMAJ400CAH: transient voltage suppressor diode, 400 V standoff, 648 V clamp, 0.6 A pulse, 400 W, bidirectional.
    • Product Details
    • Download

    Eaton SMAJ400CAH TVS Diode, 648 V Clamp

    SMAJ400CAH at a glance: transient voltage suppressor diode, 400 V standoff, 648 V clamp, 0.6 A pulse, 400 W, bidirectional.

    Key Specifications

    ParameterValue
    Orderable part numberSMAJ400CAH
    Standoff voltage (VR)400 V
    Leakage current at VR1 uA
    Breakdown voltage at IT447 V to 494 V
    Test current (IT)1 mA
    Clamping voltage at IPP648 V
    Peak pulse current0.6 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us400 W
    PackageSMA (DO-214AC)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1062

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1062; the package line above is the
    body the part is built in.

    Reading the Data Sheet

    The peak pulse power rating is a 10/1000 microsecond figure: a 400 W part takes 400 W for one millisecond, not continuously. Shorter pulses allow more current, longer ones less, which is what the derating curves in the data sheet show.

    The breakdown window spans 10.51 percent, from 447 V to 494 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 400 V standing the leakage is at most 1 uA, so the part draws 0.4 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMAJ family this is item 147 of 151 in the Eaton catalogue.

    Where This Series Fits

    The part goes across the line after the fuse, with the return path as short as the layout allows. Every centimetre of trace between the connector and the diode adds inductance, and the clamp the circuit sees is the diode clamp plus L di/dt.

    • The standoff voltage is a DC limit. On an AC line the peak of the sine has to stay below it, which for a 120 V RMS line means a part rated well above 170 V.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products