Eaton SMAJ43A 43 V 400 W TVS Diode
Eaton SMAJ43A 43 V 400 W TVS Diode

Eaton SMAJ43A 43 V 400 W TVS Diode

Share
SMAJ43A: transient voltage suppressor diode, 43 V standoff, 69.4 V clamp, 5.8 A pulse, 400 W, unidirectional.
    • Product Details
    • Download

    Eaton SMAJ43A 43 V 400 W TVS Diode

    SMAJ43A at a glance: transient voltage suppressor diode, 43 V standoff, 69.4 V clamp, 5.8 A pulse, 400 W, unidirectional.

    Specification Table

    ParameterValue
    Orderable part numberSMAJ43A
    Standoff voltage (VR)43 V
    Leakage current at VR1 uA
    Breakdown voltage at IT47.8 V to 52.8 V
    Test current (IT)1 mA
    Clamping voltage at IPP69.4 V
    Peak pulse current5.8 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us400 W
    PackageSMA (DO-214AC)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1564

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1564; the package line above is the
    body the part is built in.

    Reading the Data Sheet

    These parts are avalanching junctions, so they clamp harder than a varistor and recover without the voltage drift a metal oxide part shows after a surge. The trade is capacitance and a sharper failure mode.

    The breakdown window spans 10.46 percent, from 47.8 V to 52.8 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 43 V standing the leakage is at most 1 uA, so the part draws 0.043 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMAJ family this is item 71 of 151 in the Eaton catalogue.

    Series Positioning

    Keep the ground connection on the same layer as the diode. A clamp that has to travel through a via to reach the return plane loses most of its advantage at the edge speeds an ESD event produces.

    • The standoff voltage is a DC limit. On an AC line the peak of the sine has to stay below it, which for a 120 V RMS line means a part rated well above 170 V.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    Shenzhen Gaorunxin Technology Co., Ltd