Eaton SMAJ48CAH Transient Voltage Suppressor 48 V
Eaton SMAJ48CAH Transient Voltage Suppressor 48 V

Eaton SMAJ48CAH Transient Voltage Suppressor 48 V

Share
SMAJ48CAH: transient voltage suppressor diode, 48 V standoff, 77.4 V clamp, 5.2 A pulse, 400 W, bidirectional.
    • Product Details
    • Download

    Eaton SMAJ48CAH Transient Voltage Suppressor 48 V

    SMAJ48CAH at a glance: transient voltage suppressor diode, 48 V standoff, 77.4 V clamp, 5.2 A pulse, 400 W, bidirectional.

    Specification Table

    ParameterValue
    Orderable part numberSMAJ48CAH
    Standoff voltage (VR)48 V
    Leakage current at VR1 uA
    Breakdown voltage at IT53.3 V to 58.9 V
    Test current (IT)1 mA
    Clamping voltage at IPP77.4 V
    Peak pulse current5.2 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us400 W
    PackageSMA (DO-214AC)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1062

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1062; the package line above is the
    body the part is built in.

    What the Numbers Mean

    The peak pulse power rating is a 10/1000 microsecond figure: a 400 W part takes 400 W for one millisecond, not continuously. Shorter pulses allow more current, longer ones less, which is what the derating curves in the data sheet show.

    The breakdown window spans 10.51 percent, from 53.3 V to 58.9 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 48 V standing the leakage is at most 1 uA, so the part draws 0.048 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMAJ family this is item 78 of 151 in the Eaton catalogue.

    What This Family Is For

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The breakdown window is deliberately wide so that production spread does not leave parts conducting at the standoff voltage. Design to the minimum breakdown, not the typical.

    Frequently Asked Questions

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.