Eaton SMAJ5.0CA TVS Diode, 9.2 V Clamp
Eaton SMAJ5.0CA TVS Diode, 9.2 V Clamp

Eaton SMAJ5.0CA TVS Diode, 9.2 V Clamp

Share
SMAJ5.0CA: transient voltage suppressor diode, 5 V standoff, 9.2 V clamp, 43.5 A pulse, 400 W, bidirectional.
    • Product Details
    • Download

    Eaton SMAJ5.0CA TVS Diode, 9.2 V Clamp

    SMAJ5.0CA at a glance: transient voltage suppressor diode, 5 V standoff, 9.2 V clamp, 43.5 A pulse, 400 W, bidirectional.

    Ratings at a Glance

    ParameterValue
    Orderable part numberSMAJ5.0CA
    Standoff voltage (VR)5 V
    Leakage current at VR800 uA
    Breakdown voltage at IT6.4 V to 7 V
    Test current (IT)10 mA
    Clamping voltage at IPP9.2 V
    Peak pulse current43.5 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us400 W
    PackageSMA (DO-214AC)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1564

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1564; the package line above is the
    body the part is built in.

    What the Numbers Mean

    A transient voltage suppressor is a diode biased so that it stays off at the working voltage and breaks down in a surge. The three numbers that decide whether it fits are the standoff voltage, the breakdown window and the clamping voltage at the pulse current you expect.

    The breakdown window spans 9.375 percent, from 6.4 V to 7 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 5 V standing the leakage is at most 800 uA, so the part draws 4 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMAJ family this is item 1 of 151 in the Eaton catalogue.

    Series Positioning

    The part goes across the line after the fuse, with the return path as short as the layout allows. Every centimetre of trace between the connector and the diode adds inductance, and the clamp the circuit sees is the diode clamp plus L di/dt.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.