Eaton SMAJ6.5A 6.5 V 400 W TVS Diode
Eaton SMAJ6.5A 6.5 V 400 W TVS Diode

Eaton SMAJ6.5A 6.5 V 400 W TVS Diode

Share
SMAJ6.5A: transient voltage suppressor diode, 6.5 V standoff, 11.2 V clamp, 35.7 A pulse, 400 W, unidirectional.
    • Product Details
    • Download

    Eaton SMAJ6.5A 6.5 V 400 W TVS Diode

    SMAJ6.5A at a glance: transient voltage suppressor diode, 6.5 V standoff, 11.2 V clamp, 35.7 A pulse, 400 W, unidirectional.

    Electrical Specifications

    ParameterValue
    Orderable part numberSMAJ6.5A
    Standoff voltage (VR)6.5 V
    Leakage current at VR500 uA
    Breakdown voltage at IT7.22 V to 7.98 V
    Test current (IT)10 mA
    Clamping voltage at IPP11.2 V
    Peak pulse current35.7 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us400 W
    PackageSMA (DO-214AC)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1564

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1564; the package line above is the
    body the part is built in.

    Reading the Data Sheet

    The peak pulse power rating is a 10/1000 microsecond figure: a 400 W part takes 400 W for one millisecond, not continuously. Shorter pulses allow more current, longer ones less, which is what the derating curves in the data sheet show.

    The breakdown window spans 10.53 percent, from 7.22 V to 7.98 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 6.5 V standing the leakage is at most 500 uA, so the part draws 3.25 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMAJ family this is item 5 of 151 in the Eaton catalogue.

    Where This Series Fits

    Keep the ground connection on the same layer as the diode. A clamp that has to travel through a via to reach the return plane loses most of its advantage at the edge speeds an ESD event produces.

    • The pulse current is quoted for one waveform. A different waveform changes the allowable current, and the derating curve, not the single number, is the guide.
    • The breakdown window is deliberately wide so that production spread does not leave parts conducting at the standoff voltage. Design to the minimum breakdown, not the typical.

    Frequently Asked Questions

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message