Eaton SMAJ78AH 78 V 400 W TVS Diode
Eaton SMAJ78AH 78 V 400 W TVS Diode

Eaton SMAJ78AH 78 V 400 W TVS Diode

Share
SMAJ78AH: transient voltage suppressor diode, 78 V standoff, 126 V clamp, 3.2 A pulse, 400 W, unidirectional.
    • Product Details
    • Download

    Eaton SMAJ78AH 78 V 400 W TVS Diode

    SMAJ78AH at a glance: transient voltage suppressor diode, 78 V standoff, 126 V clamp, 3.2 A pulse, 400 W, unidirectional.

    Specification Table

    ParameterValue
    Orderable part numberSMAJ78AH
    Standoff voltage (VR)78 V
    Leakage current at VR1 uA
    Breakdown voltage at IT86.7 V to 95.8 V
    Test current (IT)1 mA
    Clamping voltage at IPP126 V
    Peak pulse current3.2 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us400 W
    PackageSMA (DO-214AC)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1062

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1062; the package line above is the
    body the part is built in.

    How to Read These Ratings

    The peak pulse power rating is a 10/1000 microsecond figure: a 400 W part takes 400 W for one millisecond, not continuously. Shorter pulses allow more current, longer ones less, which is what the derating curves in the data sheet show.

    The breakdown window spans 10.5 percent, from 86.7 V to 95.8 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 78 V standing the leakage is at most 1 uA, so the part draws 0.078 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMAJ family this is item 99 of 151 in the Eaton catalogue.

    Positioning in the Range

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The breakdown window is deliberately wide so that production spread does not leave parts conducting at the standoff voltage. Design to the minimum breakdown, not the typical.

    Frequently Asked Questions

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.