Eaton SMAJE110A 110 V 400 W TVS Diode
Eaton SMAJE110A 110 V 400 W TVS Diode

Eaton SMAJE110A 110 V 400 W TVS Diode

Share
SMAJE110A: transient voltage suppressor diode, 110 V standoff, 177 V clamp, 2.3 A pulse, 400 W, unidirectional.
    • Product Details
    • Download

    Eaton SMAJE110A 110 V 400 W TVS Diode

    SMAJE110A at a glance: transient voltage suppressor diode, 110 V standoff, 177 V clamp, 2.3 A pulse, 400 W, unidirectional.

    Key Specifications

    ParameterValue
    Orderable part numberSMAJE110A
    Standoff voltage (VR)110 V
    Leakage current at VR1 uA
    Breakdown voltage at IT122 V to 135 V
    Test current (IT)1 mA
    Clamping voltage at IPP177 V
    Peak pulse current2.3 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us400 W
    PackageSMA (DO-214AC)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11213

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11213; the package line above is the
    body the part is built in.

    Reading the Data Sheet

    A TVS is chosen after the surge source is known. The pulse current in the table is the current the part can take, so the source impedance and the coupling network decide whether the clamp column is the number the protected circuit experiences.

    The breakdown window spans 10.66 percent, from 122 V to 135 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 110 V standing the leakage is at most 1 uA, so the part draws 0.11 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMAJ family this is item 110 of 151 in the Eaton catalogue.

    Where This Series Fits

    The part goes across the line after the fuse, with the return path as short as the layout allows. Every centimetre of trace between the connector and the diode adds inductance, and the clamp the circuit sees is the diode clamp plus L di/dt.

    • The standoff voltage is a DC limit. On an AC line the peak of the sine has to stay below it, which for a 120 V RMS line means a part rated well above 170 V.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products