Eaton SMAJE16CA TVS Diode, 26 V Clamp
Eaton SMAJE16CA TVS Diode, 26 V Clamp

Eaton SMAJE16CA TVS Diode, 26 V Clamp

Share
SMAJE16CA: transient voltage suppressor diode, 16 V standoff, 26 V clamp, 15.4 A pulse, 400 W, bidirectional.
    • Product Details
    • Download

    Eaton SMAJE16CA TVS Diode, 26 V Clamp

    SMAJE16CA at a glance: transient voltage suppressor diode, 16 V standoff, 26 V clamp, 15.4 A pulse, 400 W, bidirectional.

    Electrical Specifications

    ParameterValue
    Orderable part numberSMAJE16CA
    Standoff voltage (VR)16 V
    Leakage current at VR1 uA
    Breakdown voltage at IT17.8 V to 19.7 V
    Test current (IT)1 mA
    Clamping voltage at IPP26 V
    Peak pulse current15.4 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us400 W
    PackageSMA (DO-214AC)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11213

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11213; the package line above is the
    body the part is built in.

    The Figures Explained

    A TVS is chosen after the surge source is known. The pulse current in the table is the current the part can take, so the source impedance and the coupling network decide whether the clamp column is the number the protected circuit experiences.

    The breakdown window spans 10.67 percent, from 17.8 V to 19.7 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 16 V standing the leakage is at most 1 uA, so the part draws 0.016 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMAJ family this is item 37 of 151 in the Eaton catalogue.

    Where This Series Fits

    Keep the ground connection on the same layer as the diode. A clamp that has to travel through a via to reach the return plane loses most of its advantage at the edge speeds an ESD event produces.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products