
| Parameter | Value |
|---|---|
| Orderable part number | SMAJE170CA |
| Standoff voltage (VR) | 170 V |
| Leakage current at VR | 1 uA |
| Breakdown voltage at IT | 189 V to 209 V |
| Test current (IT) | 1 mA |
| Clamping voltage at IPP | 275 V |
| Peak pulse current | 1.5 A |
| Polarity | Bidirectional |
| Peak pulse power, 10/1000 us | 400 W |
| Package | SMA (DO-214AC) |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +150 °C |
| Qualification | AEC-Q200 |
| RoHS | Compliant, halogen free |
| Data sheet | Eaton Technical Data 11213 |
Outline drawing, pad or lead geometry and the pulse derating curves are
on the pages of Eaton Technical Data 11213; the package line above is the
body the part is built in.
The standoff voltage has to sit above the highest steady state level on the line, including regulation and ripple. The breakdown voltage is then one diode drop above that, and the clamp is what the downstream circuit actually sees.
The breakdown window spans 10.58 percent, from 189 V to 209 V. Design against the minimum, because a part at the bottom of the window starts conducting first.
At 170 V standing the leakage is at most 1 uA, so the part draws 0.17 mW on the rail. Small, but it is the number that matters on a battery input.
Within the SMAJ family this is item 125 of 151 in the Eaton catalogue.
The part goes across the line after the fuse, with the return path as short as the layout allows. Every centimetre of trace between the connector and the diode adds inductance, and the clamp the circuit sees is the diode clamp plus L di/dt.
Why is the clamp voltage higher than the breakdown voltage?
The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.
Unidirectional or bidirectional?
Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.
Does the peak pulse power rating apply to any surge?
No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd