Eaton SMAJE20A 20 V 400 W TVS Diode
Eaton SMAJE20A 20 V 400 W TVS Diode

Eaton SMAJE20A 20 V 400 W TVS Diode

Share
SMAJE20A: transient voltage suppressor diode, 20 V standoff, 32.4 V clamp, 12.4 A pulse, 400 W, unidirectional.
    • Product Details
    • Download

    Eaton SMAJE20A 20 V 400 W TVS Diode

    SMAJE20A at a glance: transient voltage suppressor diode, 20 V standoff, 32.4 V clamp, 12.4 A pulse, 400 W, unidirectional.

    Specification Table

    ParameterValue
    Orderable part numberSMAJE20A
    Standoff voltage (VR)20 V
    Leakage current at VR1 uA
    Breakdown voltage at IT22.2 V to 24.5 V
    Test current (IT)1 mA
    Clamping voltage at IPP32.4 V
    Peak pulse current12.4 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us400 W
    PackageSMA (DO-214AC)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11213

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11213; the package line above is the
    body the part is built in.

    The Figures Explained

    A TVS is chosen after the surge source is known. The pulse current in the table is the current the part can take, so the source impedance and the coupling network decide whether the clamp column is the number the protected circuit experiences.

    The breakdown window spans 10.36 percent, from 22.2 V to 24.5 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 20 V standing the leakage is at most 1 uA, so the part draws 0.02 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMAJ family this is item 46 of 151 in the Eaton catalogue.

    Positioning in the Range

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd