| Parameter | Value |
|---|---|
| Orderable part number | SMAJE5.0A |
| Standoff voltage (VR) | 5 V |
| Leakage current at VR | 120 uA |
| Breakdown voltage at IT | 6.4 V to 7 V |
| Test current (IT) | 10 mA |
| Clamping voltage at IPP | 9.2 V |
| Peak pulse current | 43.5 A |
| Polarity | Unidirectional |
| Peak pulse power, 10/1000 us | 400 W |
| Package | SMA (DO-214AC) |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +150 °C |
| Qualification | AEC-Q200 |
| RoHS | Compliant, halogen free |
| Data sheet | Eaton Technical Data 11213 |
Outline drawing, pad or lead geometry and the pulse derating curves are
on the pages of Eaton Technical Data 11213; the package line above is the
body the part is built in.
The peak pulse power rating is a 10/1000 microsecond figure: a 400 W part takes 400 W for one millisecond, not continuously. Shorter pulses allow more current, longer ones less, which is what the derating curves in the data sheet show.
The breakdown window spans 9.375 percent, from 6.4 V to 7 V. Design against the minimum, because a part at the bottom of the window starts conducting first.
At 5 V standing the leakage is at most 120 uA, so the part draws 0.6 mW on the rail. Small, but it is the number that matters on a battery input.
Within the SMAJ family this is item 2 of 151 in the Eaton catalogue.
Keep the ground connection on the same layer as the diode. A clamp that has to travel through a via to reach the return plane loses most of its advantage at the edge speeds an ESD event produces.
Unidirectional or bidirectional?
Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.
What happens if the surge exceeds the rating?
The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.
How do I pick the standoff voltage?
Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.