SMAJE70A: transient voltage suppressor diode, 70 V standoff, 113 V clamp, 3.6 A pulse, 400 W, unidirectional.
    • Product Details
    • Download

    Eaton SMAJE70A 70 V 400 W TVS Diode

    SMAJE70A at a glance: transient voltage suppressor diode, 70 V standoff, 113 V clamp, 3.6 A pulse, 400 W, unidirectional.

    Specification Table

    ParameterValue
    Orderable part numberSMAJE70A
    Standoff voltage (VR)70 V
    Leakage current at VR1 uA
    Breakdown voltage at IT77.8 V to 86 V
    Test current (IT)1 mA
    Clamping voltage at IPP113 V
    Peak pulse current3.6 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us400 W
    PackageSMA (DO-214AC)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11213

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11213; the package line above is the
    body the part is built in.

    The Figures Explained

    A TVS is chosen after the surge source is known. The pulse current in the table is the current the part can take, so the source impedance and the coupling network decide whether the clamp column is the number the protected circuit experiences.

    The breakdown window spans 10.54 percent, from 77.8 V to 86 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 70 V standing the leakage is at most 1 uA, so the part draws 0.07 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMAJ family this is item 95 of 151 in the Eaton catalogue.

    Where This Series Fits

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • The standoff voltage is a DC limit. On an AC line the peak of the sine has to stay below it, which for a 120 V RMS line means a part rated well above 170 V.
    • The breakdown window is deliberately wide so that production spread does not leave parts conducting at the standoff voltage. Design to the minimum breakdown, not the typical.

    Frequently Asked Questions

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.