Eaton SMBJ11A Transient Voltage Suppressor 11 V
Eaton SMBJ11A Transient Voltage Suppressor 11 V

Eaton SMBJ11A Transient Voltage Suppressor 11 V

Share
SMBJ11A: transient voltage suppressor diode, 11 V standoff, 18.2 V clamp, 33 A pulse, 600 W, unidirectional.
    • Product Details
    • Download

    Eaton SMBJ11A Transient Voltage Suppressor 11 V

    SMBJ11A at a glance: transient voltage suppressor diode, 11 V standoff, 18.2 V clamp, 33 A pulse, 600 W, unidirectional.

    Ratings at a Glance

    ParameterValue
    Orderable part numberSMBJ11A
    Standoff voltage (VR)11 V
    Leakage current at VR1 uA
    Breakdown voltage at IT12.2 V to 13.5 V
    Test current (IT)1 mA
    Clamping voltage at IPP18.2 V
    Peak pulse current33 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us600 W
    PackageSMB (DO-214AA)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1561

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1561; the package line above is the
    body the part is built in.

    How to Read These Ratings

    A TVS is chosen after the surge source is known. The pulse current in the table is the current the part can take, so the source impedance and the coupling network decide whether the clamp column is the number the protected circuit experiences.

    The breakdown window spans 10.66 percent, from 12.2 V to 13.5 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 11 V standing the leakage is at most 1 uA, so the part draws 0.011 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMBJ family this is item 18 of 151 in the Eaton catalogue.

    Where This Series Fits

    Keep the ground connection on the same layer as the diode. A clamp that has to travel through a via to reach the return plane loses most of its advantage at the edge speeds an ESD event produces.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message