Eaton SMBJ15CA 15 V 600 W TVS Diode
Eaton SMBJ15CA 15 V 600 W TVS Diode

Eaton SMBJ15CA 15 V 600 W TVS Diode

Share
SMBJ15CA: transient voltage suppressor diode, 15 V standoff, 24.4 V clamp, 24.6 A pulse, 600 W, bidirectional.
    • Product Details
    • Download

    Eaton SMBJ15CA 15 V 600 W TVS Diode

    SMBJ15CA at a glance: transient voltage suppressor diode, 15 V standoff, 24.4 V clamp, 24.6 A pulse, 600 W, bidirectional.

    Specification Table

    ParameterValue
    Orderable part numberSMBJ15CA
    Standoff voltage (VR)15 V
    Leakage current at VR1 uA
    Breakdown voltage at IT16.7 V to 18.5 V
    Test current (IT)1 mA
    Clamping voltage at IPP24.4 V
    Peak pulse current24.6 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us600 W
    PackageSMB (DO-214AA)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1561

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1561; the package line above is the
    body the part is built in.

    How to Read These Ratings

    A TVS is chosen after the surge source is known. The pulse current in the table is the current the part can take, so the source impedance and the coupling network decide whether the clamp column is the number the protected circuit experiences.

    The breakdown window spans 10.78 percent, from 16.7 V to 18.5 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 15 V standing the leakage is at most 1 uA, so the part draws 0.015 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMBJ family this is item 32 of 167 in the Eaton catalogue.

    Positioning in the Range

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.