Eaton SMBJ15CAH 15 V 600 W TVS Diode
Eaton SMBJ15CAH 15 V 600 W TVS Diode

Eaton SMBJ15CAH 15 V 600 W TVS Diode

Share
SMBJ15CAH: transient voltage suppressor diode, 15 V standoff, 24.4 V clamp, 24.6 A pulse, 600 W, bidirectional.
    • Product Details
    • Download

    Eaton SMBJ15CAH 15 V 600 W TVS Diode

    SMBJ15CAH at a glance: transient voltage suppressor diode, 15 V standoff, 24.4 V clamp, 24.6 A pulse, 600 W, bidirectional.

    Ratings at a Glance

    ParameterValue
    Orderable part numberSMBJ15CAH
    Standoff voltage (VR)15 V
    Leakage current at VR1 uA
    Breakdown voltage at IT16.7 V to 18.5 V
    Test current (IT)1 mA
    Clamping voltage at IPP24.4 V
    Peak pulse current24.6 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us600 W
    PackageSMB (DO-214AA)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1063

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1063; the package line above is the
    body the part is built in.

    What the Numbers Mean

    A TVS is chosen after the surge source is known. The pulse current in the table is the current the part can take, so the source impedance and the coupling network decide whether the clamp column is the number the protected circuit experiences.

    The breakdown window spans 10.78 percent, from 16.7 V to 18.5 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 15 V standing the leakage is at most 1 uA, so the part draws 0.015 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMBJ family this is item 33 of 167 in the Eaton catalogue.

    Series Positioning

    Keep the ground connection on the same layer as the diode. A clamp that has to travel through a via to reach the return plane loses most of its advantage at the edge speeds an ESD event produces.

    • The standoff voltage is a DC limit. On an AC line the peak of the sine has to stay below it, which for a 120 V RMS line means a part rated well above 170 V.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products