Eaton SMBJ180CA 180 V 600 W TVS Diode
Eaton SMBJ180CA 180 V 600 W TVS Diode

Eaton SMBJ180CA 180 V 600 W TVS Diode

Share
SMBJ180CA: transient voltage suppressor diode, 180 V standoff, 292 V clamp, 2.1 A pulse, 600 W, bidirectional.
    • Product Details
    • Download

    Eaton SMBJ180CA 180 V 600 W TVS Diode

    SMBJ180CA at a glance: transient voltage suppressor diode, 180 V standoff, 292 V clamp, 2.1 A pulse, 600 W, bidirectional.

    Ratings at a Glance

    ParameterValue
    Orderable part numberSMBJ180CA
    Standoff voltage (VR)180 V
    Leakage current at VR1 uA
    Breakdown voltage at IT201 V to 222 V
    Test current (IT)1 mA
    Clamping voltage at IPP292 V
    Peak pulse current2.1 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us600 W
    PackageSMB (DO-214AA)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1561

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1561; the package line above is the
    body the part is built in.

    Reading the Data Sheet

    The standoff voltage has to sit above the highest steady state level on the line, including regulation and ripple. The breakdown voltage is then one diode drop above that, and the clamp is what the downstream circuit actually sees.

    The breakdown window spans 10.45 percent, from 201 V to 222 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 180 V standing the leakage is at most 1 uA, so the part draws 0.18 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMBJ family this is item 138 of 167 in the Eaton catalogue.

    What This Family Is For

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The breakdown window is deliberately wide so that production spread does not leave parts conducting at the standoff voltage. Design to the minimum breakdown, not the typical.

    Frequently Asked Questions

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    Shenzhen Gaorunxin Technology Co., Ltd