Eaton SMBJ18A TVS Diode, 29.2 V Clamp
Eaton SMBJ18A TVS Diode, 29.2 V Clamp

Eaton SMBJ18A TVS Diode, 29.2 V Clamp

Share
SMBJ18A: transient voltage suppressor diode, 18 V standoff, 29.2 V clamp, 20.6 A pulse, 600 W, unidirectional.
    • Product Details
    • Download

    Eaton SMBJ18A TVS Diode, 29.2 V Clamp

    SMBJ18A at a glance: transient voltage suppressor diode, 18 V standoff, 29.2 V clamp, 20.6 A pulse, 600 W, unidirectional.

    Electrical Specifications

    ParameterValue
    Orderable part numberSMBJ18A
    Standoff voltage (VR)18 V
    Leakage current at VR1 uA
    Breakdown voltage at IT20 V to 22.1 V
    Test current (IT)1 mA
    Clamping voltage at IPP29.2 V
    Peak pulse current20.6 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us600 W
    PackageSMB (DO-214AA)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1561

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1561; the package line above is the
    body the part is built in.

    Reading the Data Sheet

    The standoff voltage has to sit above the highest steady state level on the line, including regulation and ripple. The breakdown voltage is then one diode drop above that, and the clamp is what the downstream circuit actually sees.

    The breakdown window spans 10.5 percent, from 20 V to 22.1 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 18 V standing the leakage is at most 1 uA, so the part draws 0.018 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMBJ family this is item 39 of 151 in the Eaton catalogue.

    Positioning in the Range

    The part goes across the line after the fuse, with the return path as short as the layout allows. Every centimetre of trace between the connector and the diode adds inductance, and the clamp the circuit sees is the diode clamp plus L di/dt.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The breakdown window is deliberately wide so that production spread does not leave parts conducting at the standoff voltage. Design to the minimum breakdown, not the typical.

    Frequently Asked Questions

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products