Eaton SMBJ18CA 18 V 600 W TVS Diode
Eaton SMBJ18CA 18 V 600 W TVS Diode

Eaton SMBJ18CA 18 V 600 W TVS Diode

Share
SMBJ18CA: transient voltage suppressor diode, 18 V standoff, 29.2 V clamp, 20.6 A pulse, 600 W, bidirectional.
    • Product Details
    • Download

    Eaton SMBJ18CA 18 V 600 W TVS Diode

    SMBJ18CA at a glance: transient voltage suppressor diode, 18 V standoff, 29.2 V clamp, 20.6 A pulse, 600 W, bidirectional.

    Specification Table

    ParameterValue
    Orderable part numberSMBJ18CA
    Standoff voltage (VR)18 V
    Leakage current at VR1 uA
    Breakdown voltage at IT20 V to 22.1 V
    Test current (IT)1 mA
    Clamping voltage at IPP29.2 V
    Peak pulse current20.6 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us600 W
    PackageSMB (DO-214AA)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1561

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1561; the package line above is the
    body the part is built in.

    What the Numbers Mean

    The peak pulse power rating is a 10/1000 microsecond figure: a 400 W part takes 400 W for one millisecond, not continuously. Shorter pulses allow more current, longer ones less, which is what the derating curves in the data sheet show.

    The breakdown window spans 10.5 percent, from 20 V to 22.1 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 18 V standing the leakage is at most 1 uA, so the part draws 0.018 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMBJ family this is item 41 of 167 in the Eaton catalogue.

    What This Family Is For

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.