SMBJ210A: transient voltage suppressor diode, 210 V standoff, 340 V clamp, 1.8 A pulse, 600 W, unidirectional.
    • Product Details
    • Download

    Eaton SMBJ210A Transient Voltage Suppressor 210 V

    SMBJ210A at a glance: transient voltage suppressor diode, 210 V standoff, 340 V clamp, 1.8 A pulse, 600 W, unidirectional.

    Ratings at a Glance

    ParameterValue
    Orderable part numberSMBJ210A
    Standoff voltage (VR)210 V
    Leakage current at VR1 uA
    Breakdown voltage at IT237 V to 263 V
    Test current (IT)1 mA
    Clamping voltage at IPP340 V
    Peak pulse current1.8 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us600 W
    PackageSMB (DO-214AA)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1561

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1561; the package line above is the
    body the part is built in.

    The Figures Explained

    The standoff voltage has to sit above the highest steady state level on the line, including regulation and ripple. The breakdown voltage is then one diode drop above that, and the clamp is what the downstream circuit actually sees.

    The breakdown window spans 10.97 percent, from 237 V to 263 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 210 V standing the leakage is at most 1 uA, so the part draws 0.21 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMBJ family this is item 131 of 151 in the Eaton catalogue.

    What This Family Is For

    Keep the ground connection on the same layer as the diode. A clamp that has to travel through a via to reach the return plane loses most of its advantage at the edge speeds an ESD event produces.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.