Eaton SMBJ22A TVS Diode, 35.5 V Clamp
Eaton SMBJ22A TVS Diode, 35.5 V Clamp

Eaton SMBJ22A TVS Diode, 35.5 V Clamp

Share
SMBJ22A: transient voltage suppressor diode, 22 V standoff, 35.5 V clamp, 16.9 A pulse, 600 W, unidirectional.
    • Product Details
    • Download

    Eaton SMBJ22A TVS Diode, 35.5 V Clamp

    SMBJ22A at a glance: transient voltage suppressor diode, 22 V standoff, 35.5 V clamp, 16.9 A pulse, 600 W, unidirectional.

    Ratings at a Glance

    ParameterValue
    Orderable part numberSMBJ22A
    Standoff voltage (VR)22 V
    Leakage current at VR1 uA
    Breakdown voltage at IT24.4 V to 26.9 V
    Test current (IT)1 mA
    Clamping voltage at IPP35.5 V
    Peak pulse current16.9 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us600 W
    PackageSMB (DO-214AA)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1561

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1561; the package line above is the
    body the part is built in.

    Reading the Data Sheet

    A transient voltage suppressor is a diode biased so that it stays off at the working voltage and breaks down in a surge. The three numbers that decide whether it fits are the standoff voltage, the breakdown window and the clamping voltage at the pulse current you expect.

    The breakdown window spans 10.25 percent, from 24.4 V to 26.9 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 22 V standing the leakage is at most 1 uA, so the part draws 0.022 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMBJ family this is item 44 of 151 in the Eaton catalogue.

    Positioning in the Range

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • The pulse current is quoted for one waveform. A different waveform changes the allowable current, and the derating curve, not the single number, is the guide.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.