SMBJ350A: transient voltage suppressor diode, 350 V standoff, 567 V clamp, 1.1 A pulse, 600 W, unidirectional.
    • Product Details
    • Download

    Eaton SMBJ350A Transient Voltage Suppressor 350 V

    SMBJ350A at a glance: transient voltage suppressor diode, 350 V standoff, 567 V clamp, 1.1 A pulse, 600 W, unidirectional.

    Electrical Specifications

    ParameterValue
    Orderable part numberSMBJ350A
    Standoff voltage (VR)350 V
    Leakage current at VR1 uA
    Breakdown voltage at IT391 V to 432 V
    Test current (IT)1 mA
    Clamping voltage at IPP567 V
    Peak pulse current1.1 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us600 W
    PackageSMB (DO-214AA)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1561

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1561; the package line above is the
    body the part is built in.

    What the Numbers Mean

    These parts are avalanching junctions, so they clamp harder than a varistor and recover without the voltage drift a metal oxide part shows after a surge. The trade is capacitance and a sharper failure mode.

    The breakdown window spans 10.49 percent, from 391 V to 432 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 350 V standing the leakage is at most 1 uA, so the part draws 0.35 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMBJ family this is item 143 of 151 in the Eaton catalogue.

    Where This Series Fits

    The part goes across the line after the fuse, with the return path as short as the layout allows. Every centimetre of trace between the connector and the diode adds inductance, and the clamp the circuit sees is the diode clamp plus L di/dt.

    • The standoff voltage is a DC limit. On an AC line the peak of the sine has to stay below it, which for a 120 V RMS line means a part rated well above 170 V.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.