SMBJ400A: transient voltage suppressor diode, 400 V standoff, 648 V clamp, 0.9 A pulse, 600 W, unidirectional.
    • Product Details
    • Download

    Eaton SMBJ400A TVS Diode, 648 V Clamp

    SMBJ400A at a glance: transient voltage suppressor diode, 400 V standoff, 648 V clamp, 0.9 A pulse, 600 W, unidirectional.

    Specification Table

    ParameterValue
    Orderable part numberSMBJ400A
    Standoff voltage (VR)400 V
    Leakage current at VR1 uA
    Breakdown voltage at IT447 V to 494 V
    Test current (IT)1 mA
    Clamping voltage at IPP648 V
    Peak pulse current0.9 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us600 W
    PackageSMB (DO-214AA)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1561

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1561; the package line above is the
    body the part is built in.

    Reading the Data Sheet

    A TVS is chosen after the surge source is known. The pulse current in the table is the current the part can take, so the source impedance and the coupling network decide whether the clamp column is the number the protected circuit experiences.

    The breakdown window spans 10.51 percent, from 447 V to 494 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 400 V standing the leakage is at most 1 uA, so the part draws 0.4 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMBJ family this is item 146 of 151 in the Eaton catalogue.

    Where This Series Fits

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • Bidirectional parts are two junctions back to back in one package. They clamp symmetrically, at the cost of roughly double the capacitance of a unidirectional part of the same die.

    Frequently Asked Questions

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.