Eaton SMBJ40AC Transient Voltage Suppressor 40 V
Eaton SMBJ40AC Transient Voltage Suppressor 40 V

Eaton SMBJ40AC Transient Voltage Suppressor 40 V

Share
SMBJ40AC: transient voltage suppressor diode, 40 V standoff, 64.5 V clamp, 9.3 A pulse, 600 W, bidirectional.
    • Product Details
    • Download

    Eaton SMBJ40AC Transient Voltage Suppressor 40 V

    SMBJ40AC at a glance: transient voltage suppressor diode, 40 V standoff, 64.5 V clamp, 9.3 A pulse, 600 W, bidirectional.

    Key Specifications

    ParameterValue
    Orderable part numberSMBJ40AC
    Standoff voltage (VR)40 V
    Leakage current at VR1 uA
    Breakdown voltage at IT44.4 V to 49.1 V
    Test current (IT)1 mA
    Clamping voltage at IPP64.5 V
    Peak pulse current9.3 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us600 W
    PackageSMB (DO-214AA)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1561

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1561; the package line above is the
    body the part is built in.

    The Figures Explained

    A TVS is chosen after the surge source is known. The pulse current in the table is the current the part can take, so the source impedance and the coupling network decide whether the clamp column is the number the protected circuit experiences.

    The breakdown window spans 10.59 percent, from 44.4 V to 49.1 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 40 V standing the leakage is at most 1 uA, so the part draws 0.04 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMBJ family this is item 70 of 167 in the Eaton catalogue.

    What This Family Is For

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • The standoff voltage is a DC limit. On an AC line the peak of the sine has to stay below it, which for a 120 V RMS line means a part rated well above 170 V.
    • Bidirectional parts are two junctions back to back in one package. They clamp symmetrically, at the cost of roughly double the capacitance of a unidirectional part of the same die.

    Frequently Asked Questions

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.