Eaton SMBJ43AH TVS Diode, 69.4 V Clamp
Eaton SMBJ43AH TVS Diode, 69.4 V Clamp

Eaton SMBJ43AH TVS Diode, 69.4 V Clamp

Share
SMBJ43AH: transient voltage suppressor diode, 43 V standoff, 69.4 V clamp, 8.7 A pulse, 600 W, unidirectional.
    • Product Details
    • Download

    Eaton SMBJ43AH TVS Diode, 69.4 V Clamp

    SMBJ43AH at a glance: transient voltage suppressor diode, 43 V standoff, 69.4 V clamp, 8.7 A pulse, 600 W, unidirectional.

    Ratings at a Glance

    ParameterValue
    Orderable part numberSMBJ43AH
    Standoff voltage (VR)43 V
    Leakage current at VR1 uA
    Breakdown voltage at IT47.8 V to 52.8 V
    Test current (IT)1 mA
    Clamping voltage at IPP69.4 V
    Peak pulse current8.7 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us600 W
    PackageSMB (DO-214AA)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1063

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1063; the package line above is the
    body the part is built in.

    How to Read These Ratings

    These parts are avalanching junctions, so they clamp harder than a varistor and recover without the voltage drift a metal oxide part shows after a surge. The trade is capacitance and a sharper failure mode.

    The breakdown window spans 10.46 percent, from 47.8 V to 52.8 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 43 V standing the leakage is at most 1 uA, so the part draws 0.043 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMBJ family this is item 67 of 151 in the Eaton catalogue.

    Where This Series Fits

    The part goes across the line after the fuse, with the return path as short as the layout allows. Every centimetre of trace between the connector and the diode adds inductance, and the clamp the circuit sees is the diode clamp plus L di/dt.

    • The pulse current is quoted for one waveform. A different waveform changes the allowable current, and the derating curve, not the single number, is the guide.
    • The breakdown window is deliberately wide so that production spread does not leave parts conducting at the standoff voltage. Design to the minimum breakdown, not the typical.

    Frequently Asked Questions

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.