Eaton SMBJ440CAH 440 V 600 W TVS Diode
Eaton SMBJ440CAH 440 V 600 W TVS Diode

Eaton SMBJ440CAH 440 V 600 W TVS Diode

Share
SMBJ440CAH: transient voltage suppressor diode, 440 V standoff, 713 V clamp, 0.8 A pulse, 600 W, bidirectional.
    • Product Details
    • Download

    Eaton SMBJ440CAH 440 V 600 W TVS Diode

    SMBJ440CAH at a glance: transient voltage suppressor diode, 440 V standoff, 713 V clamp, 0.8 A pulse, 600 W, bidirectional.

    Key Specifications

    ParameterValue
    Orderable part numberSMBJ440CAH
    Standoff voltage (VR)440 V
    Leakage current at VR1 uA
    Breakdown voltage at IT492 V to 543 V
    Test current (IT)1 mA
    Clamping voltage at IPP713 V
    Peak pulse current0.8 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us600 W
    PackageSMB (DO-214AA)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1063

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1063; the package line above is the
    body the part is built in.

    The Figures Explained

    A transient voltage suppressor is a diode biased so that it stays off at the working voltage and breaks down in a surge. The three numbers that decide whether it fits are the standoff voltage, the breakdown window and the clamping voltage at the pulse current you expect.

    The breakdown window spans 10.37 percent, from 492 V to 543 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 440 V standing the leakage is at most 1 uA, so the part draws 0.44 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMBJ family this is item 166 of 167 in the Eaton catalogue.

    Series Positioning

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products