Eaton SMBJ7.0CA 7 V 600 W TVS Diode
Eaton SMBJ7.0CA 7 V 600 W TVS Diode

Eaton SMBJ7.0CA 7 V 600 W TVS Diode

Share
SMBJ7.0CA: transient voltage suppressor diode, 7 V standoff, 12 V clamp, 50 A pulse, 600 W, bidirectional.
    • Product Details
    • Download

    Eaton SMBJ7.0CA 7 V 600 W TVS Diode

    SMBJ7.0CA at a glance: transient voltage suppressor diode, 7 V standoff, 12 V clamp, 50 A pulse, 600 W, bidirectional.

    Ratings at a Glance

    ParameterValue
    Orderable part numberSMBJ7.0CA
    Standoff voltage (VR)7 V
    Leakage current at VR100 uA
    Breakdown voltage at IT7.78 V to 8.6 V
    Test current (IT)10 mA
    Clamping voltage at IPP12 V
    Peak pulse current50 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us600 W
    PackageSMB (DO-214AA)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1561

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1561; the package line above is the
    body the part is built in.

    How to Read These Ratings

    The standoff voltage has to sit above the highest steady state level on the line, including regulation and ripple. The breakdown voltage is then one diode drop above that, and the clamp is what the downstream circuit actually sees.

    The breakdown window spans 10.54 percent, from 7.78 V to 8.6 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 7 V standing the leakage is at most 100 uA, so the part draws 0.7 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMBJ family this is item 8 of 167 in the Eaton catalogue.

    Where This Series Fits

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • The standoff voltage is a DC limit. On an AC line the peak of the sine has to stay below it, which for a 120 V RMS line means a part rated well above 170 V.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products